beautypg.com

Calibration – Cognitive Solutions Advantage RFID Thermal Printer User Manual

Page 41

background image

M A I N T E N A N C E A N D C A L I B R A T I O N

3. Press the FEED button to clean all sides of the roller

CAUTION!

Incorrectly cleaning the printer will cause permanent damage and void the
printer’s warranty. Cognitive recommends using a certified cleaning pen for
all your printer’s cleaning requirements, P/N 60-14-00-0002.

Calibration

Calibration is the process of configuring the printer with a specific set of

parameters. Calibrate the printer when the following occurs:

• Print media type changes

• Printer skips labels

• Printer feeds blank labels

NOTE: Do NOT calibrate Blazer model printers.

To calibrate the printer, type the following commands in the DOS
Editor or Notepad:

! 0 0 0 0
VARIABLE INDEX SETTING 0
VARIABLE FEED_TYPE GAP
VARIABLE INDEX SETTING CALIBRATE
VARIABLE WRITE
END

Programming notes:

First line must use zeros with a space between each.

Second line, for a Direct Thermal printer, use index setting 0.

Third line, feed type will be GAP or BAR depending on the type of label used.

On the File menu, choose Print to send this file to the printer. The

printer READY light will flash and a label may be ejected. The printer
will not print on the label.

Wait for the READY light to turn solid green. Turn the printer OFF and
then ON.

Copyright © 2004, Cognitive.

36