5. Troubleshooting
This chapter contains information to help you solve problems. If the Switch is not functioning properly, make sure the Ethernet
Switch was set up according to instructions in this manual.
The Link LED is not lit
Solution:
Check the cable connection and remove duplex mode of the Switch.
Performance is bad
Solution:
Check the full duplex status of the Switch. If the Ethernet Switch is set to full duplex and the partner is set to half duplex,
then the performance will be poor.
100Base-TX port link LED is lit, but the traffic is irregular
Solution:
Check that the attached device is not set to dedicate full duplex. Some devices use a physical or software switch to change
duplex modes. Auto-negotiation may not recognize this type of full-duplex setting.
Why the Switch doesn’t connect to the network
Solution:
Check the LNK/ACT LED on the switch Try another port on the Switch Make sure the cable is installed properly Make sure
the cable is the right type Turn off the power. After a while, turn on power again.
Why I connect my PoE device to ES3001-4P-4Tand it cannot power on?
Solution:
1.
Please check the cable type of the connection from FSD-804(port 1 to port 4) to the other end. The cable should be an
8-wire UTP, Category 5 or above, EIA568 cable within 100 meters. A cable with only 4-wire, short loop or over 100
meters, all will affect the power supply.
2. Please check and assure the device that fully complied with IEEE 802.3af standard.
What is the power output of each IEEE 802.af PoE port?
Solution:
Each PoE port supports 48VDC, 350mA, max 15.4 watts power output. Detect and inject by the standard of IEEE 802.3af.