Step 1: Place the Switch on desktop near an AC power source.

Step 2: Keep enough ventilation space between the Switch and the surrounding objects.

When choosing a location, please keep in mind the environmental restrictions discussed in Chapter

1, Section 4, in Specification.

Step 3: Connect your Switch to 802.3af complied Power Devices (PD) and other network devices.

A. Connect one end of a standard network cable to the 10/100/1000 RJ-45 ports on the front of the Switch.

B. Connect the other end of the cable to the network devices such as printer servers, workstations or routers…etc.

Connection to the Switch requires UTP Category 5 network cabling with RJ-45 tips. For more

information, please see the Cabling Specification in Appendix A.

Step 4: Supply power to the Switch.

A. Connect one end of the power cable to the Switch.

B. Connect the power plug of the power cable to a standard wall outlet.

When the Switch receives power, the Power LED should remain solid Green.

3.2 Rack Mounting

To install the Switch in a 10-inch standard rack, follow the instructions described below.

Step 1: Place your Gigabit Ethernet Switch on a hard flat surface, with the front panel positioned towards your front side.

Step 2: Attach a rack-mount bracket to each side of the Switch with supplied screws attached to the package. Figure 3-1 shows

how to attach brackets to one side of the Switch.

Figure 3-1: Attaching the brackets to the Switch.

You must use the screws supplied with the mounting brackets. Damage caused to the parts by

using incorrect screws would invalidate the warranty.

Step 3: Secure the brackets tightly.

Step 4: Follow the same steps to attach the second bracket to the opposite side.