beautypg.com

Vlan, Vlan 34 – Interlogix MC355-1T/1S User Manual User Manual

Page 38

background image

34

IFS MC355-1T/1S User Manual

The Converter Configuration Web page includes the following configurable data:

Maximum Packet Length Provides maximum packet lengths setting for the MC355-1T/1S,

available options are 1518 bytes, 2048 bytes and 16K bytes. Default
mode is 16K bytes.

Loop Detection

Disable or enable the Loop detection function. Default mode is
Disable.

Loop Status

Displays the Loop Detection status.

Broadcast Storm Control Disable or enable the Broadcast Storm Control function. Default mode

is Disable.

Multicast Storm Control

Disable or enable the Multicast Storm Control function. Default mode
is Disable.

Unicast Storm Control

Disable or enable the Unicast Storm Control function. Default mode is
Disable.

Storm Trigger Counter

Storm Trigger Counter setting and the available options are:
64 broadcast
32 broadcast
16 broadcast
8 broadcast
Default mode is 64 broadcast.

Storm Filter Timer

Storm Filter Timer setting and the available options are:
800ms
400ms
200ms
100ms
Default mode is 800ms.

Apply Button

Press this button to save the latest configuration of the MC355-1T/1S.

VLAN

A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast
domain. It allows you to isolate network traffic so only members of the VLAN
receive traffic from the same VLAN members. Basically, creating a VLAN from a
converter is logically equivalent of reconnecting a group of network devices to
another Layer 2 switch. However, all the network devices are still plugged into
the same switch physically.

The MC355-1T/1S supports IEEE 802.1Q (tagged-based) VLAN setting in web
management page. In the default configuration, VLAN support is “No VLAN”.