beautypg.com

Mc250-4t/1cxt application connection, Wiring the power inputs, Nection 9 – Interlogix MC250-4T/1CXT User Manual

Page 15: Wiring the power inputs 9

background image

IFS MC250-4T/1CXT User Manual 9

MC250-4T/1CXT Application Connection

Two sets of the MC250-4T/1CXTs could be used to link two
local Area networks that are located in different locations.
Through a normal telephone line or coaxial cable, 100/55Mbps
(RJ-11) or 100/65Mbps (BNC) asymmetric backbone, can be
setup with one media converter in Master (CO) mode and the
other in Slave (CPE) mode.

Figure 3:

MC250-4T/1CXT

VDSL2 (RJ-11) connection

Figure 4:

MC250-4T/1CXT

VDSL2 (BNC) connection

Wiring the Power Inputs

The 6-contact terminal block connector on the top panel of the
MC250-4T/1CXT is used for two DC redundant powers inputs.
Please follow the steps below to insert the power wires.

1. Insert positive / negative DC power wires into the contacts

1 and 2 for POWER 1, or 5 and 6 for POWER 2.