Replacing the Idler Set
1. Remove the frame cover by referring to the Sections D-1 & D-
2 "Removing the Frame Covers."
2. Remove the idler spring from the pawl of the idler metal base.
(Fig. 1)
3. Loosen the idler mounting bolts, and detach the idler set. (Fig.
2)
4. Mount a brandnew idler set by using an idler mounting bolt.
5. Hang the idler spring on the pawl of the idler to give tension to
the belt.
Idler Set
EC-1200 & EC-1600
Idler Set
EC-3600 & EC-3700
Fig. 1
Idler
Idler Spring
Fig. 2
Idler
Idler Fixing
Bolt
Replacing the Idler Set