beautypg.com

Ms-7 – CatEye EC-3600 User Manual

Page 45

background image

Cateye Ergociser Series 1000 Service Manual

43

EC-1200 EC-1600 EC-3600 EC-3700

Applicable Models:

MS-7

MS-7

Replacing the Idler Set

1. Remove the frame cover by referring to the Sections D-1 & D-

2 "Removing the Frame Covers."

2. Remove the idler spring from the pawl of the idler metal base.

(Fig. 1)

3. Loosen the idler mounting bolts, and detach the idler set. (Fig.

2)

4. Mount a brandnew idler set by using an idler mounting bolt.

5. Hang the idler spring on the pawl of the idler to give tension to

the belt.

Idler Set

EC-1200 & EC-1600

Idler Set

EC-3600 & EC-3700

Fig. 1

Idler

Idler Spring

Fig. 2

Idler

Idler Fixing
Bolt

Replacing the Idler Set

This manual is related to the following products: