Replacing the CDC Sensor

1. Remove the frame cover. (See the Sections D-1 & D-2

"Removing the Frame Covers.")

2. Detach the CN-3 connector from the power supply board. (Fig.

1)

3. Cut the cable holders which fix the CDC sensor cable to the

frame.

4. Remove the defective CDC sensor set by loosening the

screws, and mount and fix the brandnew CDC sensor set.

(Fig. 2)

5. Perform the following adjustments. (Figs. 3 and 4)

Align the line on the CDC sensor with the center of the line

on the CDC magnet. (Fig. 3)

Adjust the gap between the surface of CDC sensor and the

surface of CDC magnet to be approx. 2mm. (Fig. 4)

* If the gap is inadequate, bend the metal base to secure the

specified gap.

6. Securely connect the CN-3 connector to the power supply

board. (Fig. 1)

7. Rotate the crank, and check if the pedal cadence will be

displayed on the control unit.

8. Fix the CDC sensor cable to the frame by using cable holders.

(Fig. 5)

9. Assemble the frame cover. (See the Sections D-1 & D-2

"Removing the Frame Covers.")