Ms-2 – CatEye EC-3600 User Manual
Page 40
Cateye Ergociser Series 1000 Service Manual
38
EC-1200 EC-1600 EC-3600 EC-3700
Applicable Models:
ON
MS-2
MS-2
Replacing the Workload Unit (w/ Flywheel)
Removing the Workload Unit
1. Remove the gear crank and the chain by referring to Items 1
through 4 of the Section MS-1 "Replacing the Workload Unit
(w/o Flywheel) (1)."
2. Loosen the flywheel fixing nut which is fixed to the flywheel
metal base. (Fig. 1)
3. Remove the four bolts which fix the flywheel metal base, and
remove the plain belt. (Fig. 2)
4. Remove the workload unit by referring to Items 5 and 6 of the
Section MS-1 "Replacing the Workload Unit (w/o flywheel)
(1)."
Mounting the Brandnew Workload Unit
1. Assemble the brandnew workload unit so that it will engage
with the workload unit mounting metal base of the frame (Fig.
1). [See the Item 1 of the Section MS-1 "Replacing the
Workload Unit (w/o flywheel) (2)."]
2. Hang the plain belt on the flywheel, and fix it to the flywheel
metal base with the flywheel fixing nut.
3. Provisionally fasten the metal base fixing screw (4 pieces) to
the flywheel fixing metal base and the frame respectively. (Fig.
2)
4. Mount the workload unit by referring to Items 2 to 6 of the
Section MS-1 "Replacing the Workload Unit (w/o flywheel)
(2)."
Adjusting the Flywheel
1. Adjust the flywheel by referring to the Section MS-3 "Adjusting
the Flywheel."
Flywheel
Workload Unit
EC-1600
Workload Unit
Flywheel
EC-3600 & EC-3700
Fig. 1
Flywheel
Flywheel Fixing Nut
Fig. 2
Flywheel Fixing Nut
Flywheel Metal Base
Plain Belt
Flywheel Fixing Metal Base
Metal Base Fixing
Screw