5 FAQ

5.1 Daily Maintenance

Please clean dome cover regularly to get vivid image.

Handle the cover with care. Use water to wash. Don’t use cloth to clean.
Use mild detergent to clean if there is too much dust.

Note:

The sweat from your hand may erode plating surface, your nail may scrape dome cover result in blur
image.

5.2 Problems and Solutions

SYMPTOM

CAUSE

SOLUTION

1) No self-diagnosis,

Red LED is not on.

Check power is connected or

no video signal

Your power supplying does

properly earthed.

when I connect

not apply to the power. Or

Check power supply condition

dome to power.

connection is too loose.

or check transformer.

Power off or transformer

problem.

Red LED light on the power

Use multimeter to check

board is on

dome load.

Power supplying is low

Please contact retailer to

Something wrong with power

replace power board.

board.

2) No self diagnosis.

Power supplying is inadequate.

Replace power supplying.

There is a noise

Mechanical malfunction.

Need electrical engineer help.

3) Video signal loss

Power supplying is not sufficient

Replace power supplying.

occurs in high speed

rotation.

4)Video signal is not

Circuit connection is too loose.

Connect tightly.

successive

Video switch or power problem

Need electrical engineer help.

5) Video is not clear.

Focus is in manual mode.

Control manually.

Dome cover is dirty.

Wash dome cover

6) During camera

Camera power is not in the same

When several domes are

switch, there is a tilt

Phase.

connected to one transformer,

movement in the

please connect the transformer

monitor.

output cable to the domes’ same

side.


26