4 Cable Connection

4.1 Cable Connection

The speed dome combination cable includes video cable connection port, RS485 connection port, alarm

input and output port, and power cable connection port. Please refer to the label for detailed information.

Slight difference may be found in the port amount since some functions are optional.

Name

Function

485

A

485-A. It is to control dome built-in PTZ.

B

485-B. It is to control dome built-in PTZ.

AC24V

24V power port. Connect to the power cable.

EARTH

Ground port.

HD-AVS

BNC port. HD-AVS standard signal to control the speed dome.

IN

Input audio

Audio

GND

Audio GND port.

Sheet 4-1

Relay in/out interfaces is shown below:

Name

Function

Alarm out:1

One alarm output channel. When there is an alarm from current

channel, system activates relay or not.

Alarm output relay default setup is NO. You can use the jump-

cap near the power board relay to set.

NO:Normal open alarm output.

NC:Normal close alarm output.

Alarm out_com:

Alarm input ground end.

1

Alarm in:1-2

Two alarm input channels. It is to receive relay signal from the

external alarm source. You can go to dome menu to activate

specified preset or patter.

When the activation mode is NO (normal open), dome alarms

when there is low voltage. High voltage will not activate the

alarm.

When the activation mode is NC (normal close), dome alarms

when there is high voltage. Low voltage will not activate the

alarm.

Note:

Dome alarm input message is ground mode.

Dome alarm input signal are two modes: normal open and

normal close.

GND

Alarm input ground end.

23