Replace Battery Message
The Replace Battery message has a format almost identical to the
Diagnostic message. If enabled by the user, the Replace Battery message
will be sent by the
SMARTONE when the battery charge level is at or
below the replace battery advisement level. The message will be
repeated at an interval configurable by the user for as long as the
battery remains below the advisement level. The default configuration
is for the Replace Battery message to be enabled and to be transmitted
once per day when the battery is low. The format of the Replace Battery
message is shown in table 9.
Byte Number Variable
Bits Description
0
Type Field
2
Bit (1:0) = 3 Non Standard
message type:
0
Subtype
6
Bit (7:2) = 22 for Replace
Battery Message.
1
Number of
transmissions
per burst.
4
Bits(3:0) = Number of
Transmissions (1 to 15
Transmissions)
1
Battery
Condition
1
Bit 4: 0 = Good battery. 1 =
Replace Battery
1
GPS Subsystem
Fault
1
Bit 5: 0 = GPS system OK. 1 =
Fault
1
Transmitter
Subsystem Fault
1
Bit 6: 0 = Transmitter OK. 1 =
Fault.
1
Scheduler
Subsystem Fault
1
Bit 7: 0 = OK. 1 = Fault
2
Min Interval
8
Minimum Interval between
transmission attempts ( 5
second resolution) Default is
300 seconds
3
Max Interval
8
Maximum Interval between
transmission attempts, Default
is 600 seconds
4
GPS Mean Search
Time
8
Unsigned binary count in
seconds for mean GPS search to
acquire
5,6
# GPS Fails
16
Unsigned binary count of
failed GPS attempts since last
Diagnostic message
7,8
# Transmissions 16
# of transmissions since last
Diagnostic message
Table 9 - Replace Battery Message
Contact Service Provider Message
The
SMARTONE will send a Contact Service Provider message when an
internal fault is detected. The
SMARTONE will send one such message
upon the detection of an internal fault. It will then attempt to
continue to operate normally. The
SMARTONE will not send another