Commands – overview – Flintec LDU 68.2 User Manual

Page 12

background image

LDU 68.1 & 68.2 Technical Manual, Rev. 12 January 2010

Page 12 of 28

7.

Commands – Overview

Command Short

description

Parameter

value

Page

AD

Communication: Device Address

0...255

23

A0/A1

Setpoints: Output of Gros Value (0) or Net Value(1)

0 or 1

22

BR

Communication: Baud Rate

9600…115200 baud 23

CE

Calibration: Open Calibration Sequence; Read TAC Counter

0...65535

14

CI

Calibration: Minimum Output Value

–99999...0 d

14

CG

Calibration: Set Calibration Gain (Span) at Load > Zero

0...99999

15

CL

Communication: Close Device

None

23

CM

Calibration: Set Maximum Output Value

1...99999 d

14

CS

Save the Calibration Data (CM, CI, DS, DP, CZ, CG, etc.) to EEPROM

None

15, 24

CZ

Calibration: Set Calibration Zero Point – scale without load

None

14

DP

Calibration: Set Decimal Point Position

0...5

14

DS

Calibration: Set Display Step Size

1, 2, 5, 10…, 200

14

DX

Communication: Set Half-duplex (0) or Full-duplex (1)

0 or 1

23

FD

Factory default settings: Write data to EEPROM (TAC protected)

None

15

FF

Digital filter: Moving Average

0…15

17

FL

Digital filter: Filter Cut-off Frequency

0...7

17

GA

Trigger function: Get Average Value

None

25

GF

Output: Get Filtered Value

None

19

GG

Output: Get Gross Value

None

19

GI

Saves an image file from the LDU’s EEPROM

None

24

GN

Output: Get Net Value

None

19

GS

Output: Get ADC Sample Value

None

19

GT

Output: Get Tare Value

None

19

GW

Output: Get Data String “Net/Gross/Status“

None

19

H0/H1

Setpoints: Hysteresis for Setpoint S0 (H0) or S1 (H1)

-99999...+99999 d

22

ID

Device information: Identify Device

None

13

IM

Digital output: Enable Output for External Control

0000...0011

21

IN

Digital input: Input Status

None

21

IO

Digital output: Output Status

0000...0011

21

IS

Device information: Identify Device Status

None

13

IV

Device information: Identify Firmware Version

None

13

MT

Trigger function: Measuring Time for Averaging

0...500 ms

25

NR

Motion detection: No-motion Range

0...65535 d

16

NT

Motion detection: No-motion Time Period

0...65535 ms

16

OP

Communication: Open Device xxx

0...255

23

PI

Download a saved image file to the LDU’s EEPROM

None

24

RS

Device information: Read serial number

None

13

RT

Scale function: Reset Tare and Switch to Gross Indication

None

18

RZ

Scale function: Reset Zero Point

None

18

SA

Auto-transmit: Send Triggered Average Value automatically

None

20, 25

SD

Trigger function: Start Delay

0...500 ms

25

SF

Auto-transmit: Send Filtered Net Value continuously (Display Mode only) None

20

SG

Auto-transmit: Send Gross Value continuously

None

20

SN

Auto-transmit: Send Net Value continuously

None

20

S0/S1

Setpoints: Setup of Setpoints S0 and S1

-99999...+99999 d

22

SR

Reset Firmware (Warm Start)

None

13

SS

Save Setpoint Data (S0, S1, H0, H1, A0 and A1) to EEPROM

None

24

ST

Scale function: Set Tare and Switch to Net Indication

None

18

SW

Auto-transmit: Send Data String „Net/Gross/Status“ continuously

None

20

SZ

Scale function: Set Zero

None

18

TD

Communication: Transmission delay

0…255 ms

23

TE

Trigger function: Trigger on Rising Edge (1) or Falling Edge (0)

0 or 1

25

TL

Trigger function: Trigger Level

0...99999 d

26

TR

Trigger function: Software Trigger

None

25

UR

Digital filter: Update Rate

0...2

17

WP

Save the Setup Data (FL, NR, NT, AD, BR, DX) to EEPROM

None

24

ZI

Calibration: Initial Zero Range

0...99999 d

15

ZT

Zero Tracking: Disable (0) or Enable (1)

0 or 1

15