5.10.2. CROSSOVER
Crossover parameters group contains FILTER TYPE, EDGE LINK and FREQUENCY parameters
for each of the two crossover filters (low-pass and high-pass). These filters split the frequency spectrum
in different parts matching each speaker.
FILTER TYPE selects the crossover filter type. Following filter types are available:
Butterworth 6, 12, 18 or 24dB/oct
Bessel 12, 18 or 24dB/oct
Linkwitz-Riley 12 or 24dB/oct
EDGE LINK links cut-off frequencies of a filter and of its opposite (high-pass low-pass,
low-pass high-pass) in other channels, to edit only one parameter but simultaneously control
two. For example, if you activate EDGE LINK between OUT1 crossover low-pass and OUT2,
editing OUT1 low-pass filter frequency value will simultaneously change OUT2 high-pass filter
frequency value.
FREQUENCY is made of a potentiometer and a linked numerical value to set the filter cut-off
frequency within 20Hz – 20 kHz range.
5.10.3. REMOTE
REMOTE section assigns available external remote volume controls to
AMIC24i processing channels.
CONTROL parameter displays a list of available volume controls for the
channel:
None means no remote volume control will affect the channel volume
A and B allow to select which of the two external controls will edit the channel volume.
This section level meter displays the processing channel current value (when .amiclab2 is
connected with the hardware).