Table 6 — electrical data, 064 units (cont) – Carrier NP034-074 User Manual

Page 29

background image

Table 6 — Electrical Data, 064 Units (cont)

460-3-60 (V-Ph-Hz)

VOLTAGE

RANGE

COMPR

NO. 1

COMPR

NO. 2

OFM

IFM

BASE UNIT

ONLY

EXHAUST

FAN

ELECTRIC

HEAT*

BASE UNIT WITH

EXHAUST FAN

AND/OR

ELECTRIC HEAT*

RLA

LRA

RLA

LRA

Total

FLA

Hp

FLA

MCA

MOCP

Total

Hp

Total

FLA

kW

FLA

MCA

MOCP

414-508

50.6

253.0

50.6

253.0

10.8

15.0

21.0

145.6

175

10.0

15.2

160.8

200

15.0

22.0

167.6

200

20.0

28.0

173.6

200

36

46.3

145.6

175

72

93.0

145.6

175

108†

139.0

200.0

200

10.0

15.2

36

46.3

160.8

200

10.0

15.2

72

93.0

160.8

200

10.0

15.2

108†

139.0

200.0

200

15.0

22.0

36

46.3

167.6

200

15.0

22.0

72

93.0

167.6

200

15.0

22.0

108†

139.0

200.0

200

20.0

28.0

36

46.3

173.6

200

20.0

28.0

72

93.0

173.6

200

20.0

28.0

108†

139.0

200.0

200

20.0

27.0

151.6

200

10.0

15.2

166.8

200

15.0

22.0

173.6

200

20.0

28.0

179.6

225

36

46.3

151.6

200

72

93.0

151.6

200

108†

139.0

207.5

225

10.0

15.2

36

46.3

166.8

200

10.0

15.2

72

93.0

166.8

200

10.0

15.2

108†

139.0

207.5

225

15.0

22.0

36

46.3

173.6

200

15.0

22.0

72

93.0

173.6

200

15.0

22.0

108†

139.0

207.5

225

20.0

28.0

36

46.3

179.6

225

20.0

28.0

72

93.0

179.6

225

20.0

28.0

108†

139.0

207.5

225

25.0

34.0

158.6

200

10.0

15.2

173.8

200

15.0

22.0

180.6

225

20.0

28.0

186.6

225

36

46.3

158.6

200

72

93.0

158.7

225

108†

139.0

216.3

250

10.0

15.2

36

46.3

173.8

200

10.0

15.2

72

93.0

173.8

225

10.0

15.2

108†

139.0

216.3

250

15.0

22.0

36

46.3

180.6

225

15.0

22.0

72

93.0

180.6

225

15.0

22.0

108†

139.0

216.3

250

20.0

28.0

36

46.3

186.6

225

20.0

28.0

72

93.0

186.6

225

20.0

28.0

108†

139.0

216.3

250

30.0

40.0

164.6

200

10.0

15.2

179.8

225

15.0

22.0

186.6

225

20.0

28.0

192.6

225

36

46.3

164.6

200

72

93.0

166.2

250

108†

139.0

223.7

250

10.0

15.2

36

46.3

179.8

225

10.0

15.2

72

93.0

179.8

250

10.0

15.2

108†

139.0

223.7

250

15.0

22.0

36

46.3

186.6

225

15.0

22.0

72

93.0

186.6

250

15.0

22.0

108†

139.0

223.7

250

20.0

28.0

36

46.3

192.6

225

20.0

28.0

72

93.0

192.6

250

20.0

28.0

108†

139.0

223.7

250

LEGEND

CV

Constant Volume

ETL

ETL Testing Laboratory

FLA

Full Load Amps

Hp

Nominal Horsepower

IFM

Indoor (Evaporator) Fan Motor

LRA

Locked Rotor Amps

MCA

Minimum Circuit Amps (for wire sizing)

MOCP — Maximum Overcurrent Protection
OFM

Outdoor (Condenser) Fan Motor

RLA

Rated Load Amps

*Electric heat available on 50 Series vertical discharge units.

†108 kW available on CV applications only.

NOTES:
1. Electric resistance heaters are rated at 208/240 v, 480 v, or 575 v. To

determine heater capacity (kW) at unit operating voltage, multiply 240 v,
480 v, or 575 v capacity by appropriate multiplier below.

MULTIPLICATION FACTORS

HEATER kW

RATING

VOLTAGE

DISTRIBUTION

V-3-60

MULTIPLICATION

FACTOR

240

200
208
230
240

0.694
0.751
0.918
1.000

480

440
460
480

0.840
0.918
1.000

575

550
575
600

0.915
1.000
1.089

Electric heaters are tested and ETL approved at maximum
total external static pressure of 1.9 in. wg.

2. Boldface indicates 48 and 50 Series units. All other data is for 50 Series

units only.

29