beautypg.com

Drawmer DC2476 Digital Mastering Processor User Manual

Page 17

background image

17

GLOBAL - DIGIO

The selected sample rate is shown
on the screen in a blackened box.

Rotate the control knob to the
required input signal. Push the
control knob to select the function.

When the Output SRate is being
adjusted the previous value is shown
in a black box and the selected value
is in a clear box. When the new value
has been selected, the old value is
cleared and the new box is blackened.

When Pv is selected (using the
Chain/Param button).
Use the Left or Right button
to select either the Analogue In
SRate, Digital In/Clk or the Output
SRate.

Displays the clock frequency for either
digital or analogue.

Push the knob to select either the
input or output sample rate.

GLOBAL - EXTERNAL CLOCK

If a digital input has been selected
but no digital devise is connected then
the sample rate leds flash.

This page allows the External Clock
on the rear of the unit to be set to
either the input or output sample rates
as set on the DIGIO page.

When the OP sample rate is set to
(as input) the digital output
will be at the same rate as the input
sample rate or if an EXT is selected
and a wordclock source is connected
to the wordclock input BNC, the dig-
ital outputs will be at this external
word clock sample rate.