Specifications – Comtrol RocketPort 550 uPCI MS-DOS User Manual
Page 16
![background image](/manuals/672091/16/background.png)
16
9. Specifications
RocketPort 550 & RocketPort 550 Universal
Specification
Baud rate :
RP550 PCI 4 (RJ45 and QUAD)
50 to 460.8K baud
RP550 PCI 8 (RJ11 and OCTA)
50 to 115.2K baud
RP550 PCI 8 and 16 Port (uses interface box)
50 to 230.4K baud
RP550 UPCI 4 (RJ45 and QUAD)
50 to 115.2K baud
RP550 UPCI 8 (RJ11 and OCTA)
50 to 115.2K baud
RP550 UPCI 8 and 16 Port (uses I/F box)
50 to 230.4K baud
Note : Throughput (CPS) is dependant upon platform, operating system & application s/w
Bus interface
32 Bit PCI (5V) UPCI (5V &
3.3V)
Control by device driver
Data bits
5,6, 7 or 8
Parity
Odd, Even,Mark, Space or None
Stop bits
1, 1.5, or 2
Note: Certain combinations of data bits, parity or stop bits may not be allowed by some
operating systems.
BroadPort 550 Universal
Specification
Baud rate :
BP 550 UPCI 8 (SMPTE)
50 to 230.4K baud
BP 550 UPCI 16 (SMPTE)
50 to 230.4K baud
Note : Throughput (CPS) is dependant upon platform, operating system & application s/w
Bus interface
UPCI (5V & 3.3V)
Control by device driver
Data bits
5,6, 7 or 8
Parity
Odd, Even,Mark, Space or None
Stop bits
1, 1.5, or 2
Note: Certain combinations of data bits, parity or stop bits may not be allowed by some
operating systems.
Environmental Condition
Specification
Air temperature :
System on
0 to 40ºC
System off
-20 to 85ºC
Humidity (non-condensing)
System on
8 to 80%
System off
20 to 80%
Altitude
0 to 10,000 feet
MTBF
Greater than 30 years