Interchangevs specifications, Table 11. operating conditions, Table 12. specifications – Comtrol VS1100 Configuration Guide User Manual
Page 27
Hardware Conditions
27
InterChangeVS Specifications
Hardware Conditions
The following table lists the InterChangeVS unit conditions.
Hardware Specifications
The following table lists the InterChangeVS unit specifications.
Table 11. Operating Conditions
Condition
Value
Heat output:
InterChangeVS 1000
InterChangeVS 1100
51.2
BTU/Hr
34.1
BTU/Hr
Air temperature:
System on
System off
0 to 40
o
C
-20 to 85
o
C
Altitude
0 to 10,000 feet
Mean Time between Failures:
InterChangeVS 1000
InterChangeVS 1100
7.8 years
20.9 years
Humidity (non-condensing):
System on
System off
8% to 80%
20% to 80%
Table 12. Specifications
Topic
Specification
Maximum base units per server
Dependent on operating system
Maximum VS1100 port extenders
per VS1000 base unit
3
Maximum number of serial ports per
VS1000/VS1100 combined system
64
Maximum Baud Rate
VS1000/VS1100
230.4K bps