Installation
KEY
A
Gun Air Inlet
G
Pump Ground Wire
B
Gun Fluid Inlet
H
Air Line Filter
c
Bleed-Type Master
J
Fluid Drain Vaive
Air Vaive
K
Gun Air Hose
D
Main Air Supply Line
L
Gun Fluid Hose
E
Pump Air Regulator
M
Fluid Regulator Kit
F
Gun Air Regulator,
N
Fluid Filter
p/n 110-776, lOpsI
(0.7 bar)Maximum
Outlet Pressure
P
Air Pressure
Relief Vaive
Fig.1
The typical installation shown in Fig.1 is only a guide
for selecting and installing air-assisted airless spray
systems. It is not an actual system design. Contact
your Graco representative for assistance in designing
a system to meet your needs.
The Graco fluid pump Model 217-523 is designed for
use in air-assisted airless systems. It has a maximum
working pressure of 950 psi (66 bar). See instruction
manual 307-595 for information on this pump.
Ventilate the Spray Booth
----------------------- WARNING----------------------------
Required Accessories
To prevent hazardous concentrations of toxic and/
or flammable vapors, spray only in a properly ven
tilated spray booth.
Never operate the spray gun unless ventilation
fans are operating.
Check and follow all of the National, State and
Local codes regarding air exhaust velocity
requirements.
■WARNING
Two accessories, the bleed-type master air valve
(C), and the fluid drain valve (J) are required for
your system to reduce the risk of serious injury
from moving parts, splashing, or fluid injection
when shutting off the pump.
The bleed-type master air valve
(located down
stream of the pump air regulator) relieves air
trapped between the valve and the pump, after
the pump is shut off. Trapped air can cause the
pump to cycle unexpectedly and result in serious
injury if you are adjusting or repairing the pump.
The fluid drain valve(s)
helps relieve fluid pressure
in the displacement pump, hose and gun when
shutting off the pump. Triggering the gun to relieve
pressure may not be sufficient, especially if there
is a clog in the hose, gun, or tip.
6