Service
A A
— DETAIL D —
Fluid Needle
Packings (47)
A. A
A
A
A
A
A
A
A
A
A
A
A A 30
SERVICE NOTES:
Gasket (33) must be replaced if fluid connector (67 or 1-see page 14) is removed or replaced.
Fluid leakage into air chambers may result if new gasket is not Instailed.
Lubricate threads
Apply anaerobic pipe sealant to threads
Apply high strength sealant to threads
Thread nut to bottom thread of needle
U-cup lips face inward
Torque to 23-27 ft-lb (31 -37 N*m)
Torque to 20-24 ft-lb (27-32 N«m)
Torque to 15-19 ft-lb (20-26 N»m)
Torque to 4-6 in-lb (5-8 N«m)
Fig. 7
307-947