6

A05099

Fig. 10 -- Remove Furnace Door

A04150

Fig. 11 -- Control Switch to OFF

O

F

F

2

3

1

M

P

ON

O

F

F

C

A06338

Fig. 12 -- Control Switch to OFF

A04151

A04151

Fig. 13 -- Control Switch to ON

O

F

F

2

3

1

M

P

ON

O

F

F

C

A06339

Fig. 14 -- Control Switch to ON

7. Replace main furnace door. (See Fig. 15.)
8. Turn ON the electrical supply to the furnace and wait 1

minute. (See Fig. 16.)

9. Open the external manual gas valve. (See Fig. 17.)

10. Set the room thermostat to a temperature slightly above

the room temperature. This will automatically signal the

furnace to start.

11. When the furnace receives the start signal, the inducer is

started. When the pressure switch senses that there is suf--

ficient combustion air, the hot surface igniter is energized.
After the hot surface igniter is heated for 17 seconds, the
gas valve permits gas to flow to the main burners. After

ignition and a time delay of about 30 sec, the furnace
blower will start. Variable--capacity furnaces start at low

speed until the control makes the necessary adjustments to
operate the blower at either the low-- or high--heat speed.

A05100

Fig. 15 -- Furnace Door Replaced

A92359

Fig. 16 -- Turn On Electrical Supply