beautypg.com

Troubleshooting, Sr31 shows – Kenmore 625.34859 User Manual

Page 22

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

SECTION 5

SERVICE TECH. INFORMATION

5A.

TROUBLESHOOTING

VALVE POSITION INDICATORS: Depending on the

valve position, the following indicators show in the
display:

INDICATOR VALVE POSITION

Serv

................ service

Fill

.................... fill

Brine

................ bhning/brine rinse

Bkwsh

............. backwash

Rinse

.............. fast rinse

When the valve is rotating from 1 cycle to another,
both indicators flash. For example, if the valve is in
transition between fill and brining, both Fill and
Brine flash. Upon reaching brining position. Fill
goes off and Brine is on steady. The time display
shows the minutes of the cycle remaining.

NOTE: If the face plate is left in a diagnostic display

(or a flashing display when setting times or

hardness), present time automatically returns if a
button is not pressed within 4 minutes. To return
to the diagnositc display, repeat step 2.

OTTIER INFORMATION While in this diagnostic screen,
the following infomiation is avtulable tmd may be
beneficial for vtmous reasons. This information is
rettuned by the computer from the first time electrical
power is applied to the face plate.

... Press the UP button to display the number of days

this face plate has had electrical power applied.

...Press the DOWN button to display the number of

regenerations initiated by this face plate since the SR
code number was entered.

2.

Press the ON/OFF-HOLD button to advance the

valve to each position and observe the switch
and position indicators to verify component
operation, or to possibly isolate a defect.

3.

Press and hold the SELECT button for 3 seconds

until...

...SR31 shows.

This code identifies the softener nominal capacity
size. If the wrong number shows, the softener will
operate on incorrect programming. Do the following
as needed.

SR31 does show — Press the SELECT button to
return the present time display.

To change SR numher — Press the UP or DOWN

button until SR31 shows. Then, press the SELECT
button and reset the timer...page 6.

FACE PLATE REPLACEMENT: BE SURE THE VALVE IS IN

SERVICE POSITION (OBSERVE VALVE CYCLE INDICATOR)

WHEN REPLACING THE FACE PLATE.

If, after installing and programming the replacement face
place, the valve is not in service position, do the following
to assure correct cycle orientation, or timing, between the
face plate and valve.

Use the MANUAL ADVANCE procedures, page 23. With the
RECHARGE NOW button, advance through the recharge
cycles until the valve stops in service position, and RE­
CHARGE no longer flashes in the timer.

NOTE: The valve motor may automatically drive through
several valve positions while searching for service. If an er­
ror code occurs, unplug the transformer, then plug in again.

position
markers

22

This manual is related to the following products: