Troubleshooting, Back of timer (pwa), Always make these initial checks first – Kenmore 625.34859 User Manual
Page 20: Service tech. information 5a. troubleshooting
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
SECTION 5
SERVICE TECH. INFORMATION
5A.
TROUBLESHOOTING
Keep this manual with your water softener. If repairs are needed, the service technician must have the informa
tion on the following 8 pages. For telephone assistance, call toll free, 1-800-426-9345.
WIRING SCHEMATIC
24VAC
Transformer
Turbine
Sensor
GND
+5
BACK OF TIMER
(PWA)
POS .'TURBINE
MOTOR
............. D D
Motor, 24VAC
o
Position
o.,„
Switch
NO
Sears Water Line
for Customer Assistance
1
-
800
-
426-9345
SALT
LEVEL
ADJUST
SIGNAL
LIGHT
ADJUST
LOW
^
<;
ûit
^
TV
SELECT
ON/OFF
HOLD
RECHARGE TONIGHT
RECHARGE NOW
V
um
Deluxe Demand Water Softener
with Duai Segment Eiectronic Dispiay
ALWAYS MAKE THESE INITIAL CHECKS FIRST
1.
D(jes the time display shctw the cctrrect time (tf day?
—If display is blank, check power source to the soft
ener.
—If time is flashing, pctwer was (tff for ttver 24 hcturs. The
scjftener resumes nctrmal (tperatictn but regeneratictns
occur at the wrong time.
—If an errctr cctde (Example: Err.3) shctws in the face plate
display, get t(J
AtrrOMATIC
ELECTRONIC DIAGNOS
TICS.
2.
Plumbing bypass valve(s) must be in Full Service
position.
3.
The inlet and outlet pipes must connect to the softener
inlet and outlet respectively.
4.
Is the transfetrmer plugged intet a “live”, gretunded wall
outlet, and the power cable fastened securely?
5.
The valve drain hetse must be free (tf kinks and sharp
bends, and nett elevated (tver 8 ft. alxtve the fktetr.
REMOVE THE TOP COVER AND SALT TANK COVER
6
.
Is there salt in the stetrage tank?
7.
Is the brine tubing connected? (See water flow
diagrams).
8
.
Is the brine valve float set right? (See page 23).
9.
Press the SELECT buttetn 2 times
to
display the hardness
setting. Be sure it is the cctrrect setting fetr the
hcjusehctld’s water supply. (Make a hardness test (tf the
raw water and cctmpare with the hardness setting. Alsct
test a soft water sample to verify if a problem exists.)
Press the SELECT buttetn twice metre t(t return t(t
present time in the display.
If yctu dtt nett find the pretblem after making initial checks,
det the
MANUAL
INITIATED ELECTRONIC DIAGNOSTICS,
and the MANUAL ADVANCE REGENERATION CHECK.
20