Checking for LP gas leaks
Never test for leaks with a flame. Prior to first use, at
the beginning of each season, or every time your LP
gas tank is changed, you must check for gas leaks.
1. Make a 50/50 (soap/water) mild soap solution.
2. Turn the control knobs to full OFF position; then
turn gas ON at supply tank.
3. Apply the soap solution with a clean brush to all
gas connections. See below. If growing bubbles
appear in the solution the connections are not
properly sealed. Check each fitting and tighten or
repair as necessary.
Gas Connection Leak Check
4. If you have a gas connection leak you cannot
repair, turn gas OFF at supply tank, disconnect
fuel line from your grill and call 1-800-4-MY-HOME
or your gas supplier for repair assistance.
5. Also apply soapy solution to the tank seams. See
below. If growing bubbles appear, shut tank OFF
and do not use or move it! Contact an LP gas
supplier or your fire department for assistance.
Gas Tank Leak Check
Grill Lighting Instruction
Grill Lighting Instructions for Main Burners
1. Do not smoke while lighting grill or checking gas
supply connections.
2. Be sure that LP gas tank is sufficiently full.
A
WARNING
Failure to open grill lid during the lighting
procedure could result in a fire or explosion
that could cause serious bodily injury, death,
or property damage.
3.
4.
5.
Be sure all gas connections are securely
tightened.
Cpen the grill main lid and side burner lid.
Push and turn any main burner knob to^HI
position, holding knob and Electronic i^tion
button for 3 to 5 seconds to light burner.
6
.
7.
8
.
To light additional burners, turn burner
knob(s) to^ HI. Push and hold electronic
ignition button to light burner. Adjust knob(s)
to desired setting.
If the burner does not light after 5 seconds,
turn knob to CFF. Turn gas CFF at LP tank
and wait 5 minutes for gas to clear. Then
turn gas CN at tank and repeat step 5
If burner still does not light, see Match
Lighting section and If Grill Still Fails to Light
section on following page.
USING THE SIDE BURNER:
Inspect the gas supply hose prior to turning the gas
“ON”. If there is evidence of cuts, wear or abrasion,
it must be replaced prior to use. Do not use the
side burner if the odor of gas is present.
W A R N IN G : A lw ays keep your face and body as
far aw ay from the burner as possible w hen
lighting.
LIGHTING INSTRUCTIONS FOR SIDE BURNER
1. Open side burner lid fully.
2. Push and turn side burner knob to J^HI position.
Push and hold Electronic Ignition button for 3-5
seconds to light burner. If the side burner does
not light after 5 seconds, turn knob to OFF. Turn
gas OFF at LP tank and wait 5 minutes for gas
to clear. Then turn gas ON at tank and repeat
step 2.
3. If burner still does not light, see Match Lighting
section and If Grill Still Fails to Light Section on
following page.
13