Testing – Kenmore 415.1615111 User Manual
Page 6
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Hold coupling nut and regulator
as shown for proper connection
to LP tank valve.
Leak
Testing
Valves, Hose and Regulator
1. Turn all grill control knobs to OFF.
2. Be sure regulator is tightly connected to LP tank.
3. Completely open LP tank valve by turning OPD hand wheel
counterclockwise. If you hear a rushing sound, turn gas off
immediately. There is a major leak at the connection.
Correct before proceeding by calling Sears for replacement
parts at 1-800-4-MY-HOME®.
4. Brush soapy solution onto areas where bubbles are shown in
picture below:
Never remove
threa
orifice at end of vc
6. Turn the coupling nut clockwise and tighten to a full stop. The
regulator will seal on the back-check feature in the LP tank
valve, resulting in some resistance. An additional one-half to
three-quarters turn is required to complete the
connection. Tighten by hand only — do not use tools.
NOTE:
If you cannot complete the connection, disconnect regulator
and repeat steps
5
and 6. If you are still unable to complete
the connection, do not use this regulator!
Call 1-800-4-MY-HOME® for identical replacement parts.
• Do not insert any tool or foreign objects into the valve
outlet or safety relief valve. You may damage the valve
and cause a leak. Leaking propane may result in
explosion, fire, severe personal injury, or death.
• If a leak is detected at any time, STOP and call the fire
department.
• If you cannot stop a gas leak, immediately close LP tank
valve and call LP gas supplier or your fire department!
5
. If “growing” bubbles appear, there is a leak. Close LP tank
valve immediately and retighten connections. If leaks
cannot be stopped do not try to repair. Call Sears for
replacement parts at 1-800-4-MY-HOME®.
6. Always close LP tank valve after performing leak test by
turning hand wheel clockwise.
• Never attempt to attach this grill to the self-contained
LP gas system of a camper trailer or motor home.
• Do not use grill until leak-tested.
6 • 464220311