Awarning, Electrical ccinnectlon – Kenmore ELITE OASIS 110.6703 User Manual
Page 8
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Electrical Ccinnectlon
Power Supply Cord
Direct Wire
AWARNING
AWARNING
M
M
Fire Hazard
Fire Hazard
Use
a new UL listed
30
amp power supply cord.
Use 10 gauge solid copper wire.
Use a UL
listed strain
relief.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire
(green or bare wire) must be connected to
green
ground
connector.
Ground wire
(green
or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Securely tighten all electrical connections.
Failure to do
so
can result in death, fire, or
electrical shock.
Failure to do so can result in death,
fire,
or
electrical shock.
1. Disconnect power.
2.
Remove the hold-down screw and terminal block cover.
E
F
A. Terminal block cover
B. Hold-down screw
C. External ground conductor screw
D. Center, silver-colored terminal block screw
E. Neutral ground wire
F. Hole below terminal block opening
3.
Install strain relief.
Style 1: Power supply cord strain relief
■ Remove the screws from a %" (1.9 cm) UL listed strain relief
(UL marking on strain relief). Put the tabs of the two clamp
sections into the hole below the terminal block opening so
that one tab is pointing up and the other is pointing down,
and hold in place. Tighten strain relief screws just enough to
hold the two clamp sections together.
B
C
D
A. Strain relief tab pointing up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing down