Determine vent path

Select the route that will provide the straightest and most
direct path outdoors.

Plan the installation to use the fewest number of elbows and

turns.

When using elbows or making turns, allow as much room as

possible.

Bend vent gradually to avoid kinking.

Use the fewest 90° turns possible.

Install ¥eri Sy^em

1.

Install exhaust hood. Use caulking compound to seal exterior

wall opening around exhaust hood.

2.

Connect vent to exhaust hood. Vent must fit inside exhaust

hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.

3.

Run vent to dryer location. Use the straightest path possibie.

See “Determine vent path” in “Plan Vent System.” Avoid 90°

turns. Use clamps to seal all joints. Do not use duct tape,

screws or other fastening devices that extend into the interior
of the vent to secure vent.

Determine vent length and elbows needed for best

drying performance

■ Use the following Vent system chart to determine type of vent

material and hood combinations acceptable to use.

NOTE:

Do not use vent runs longer than those specified in

the Vent system chart. Exhaust systems longer than those

specified will;

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and
increased energy usage.

The Vent system chart provides venting requirements that will

help to achieve the best drying performance.

Vent system chart

NOTE:

Bottom exhaust performance is equivalent to adding two

elbows. To determine maximum exhaust length, add two elbows

to the chart.

NOTE:

Performance of rear exhaust to either side of the dryer is

equivalent to adding one elbow. To determine maximum exhaust

length, add one elbow to the chart.

Number of

90° turns

or elbows

Type of

vent

Box or

Louvered

hoods

Angled

hoods

0

Rigid metal

Flexible metal

64 ft (20 m)

36 ft (11 m)

58 ft (17.7 m)
28 ft (8.5 m)

1

Rigid metal

Flexible metal

54 ft (16.5 m)

31 ft (9.4 m)

48 ft (14.6 m)

23 ft (7 m)

2

Rigid metal

Flexible metal

44 ft (13.4 m)

27 ft (8.2 m)

38 ft (11.6 m)

19 ft (5.8 m)

3

Rigid metal

Flexible metal

35 ft (10.7 m)

25 ft (7.6 m)

29 ft (8.8 m)

17 ft (5.2 m)

4

Rigid metal

Flexible metal

27 ft (8.2 m)
23 ft (7 m)

21 ft (6.4 m)

15 ft (4.6 m)

Excessive Weight Hazard

Use two or more people to move and install dryer.

Failure to do so can result in back or other injury.

To protect the floor, use a large, flat piece of cardboard from
the dryer carton. Place cardboard under the entire back edge

of the dryer.

Firmly grasp the body of the dryer (not the top or console
panel). Gently lay the dryer on the cardboard. See illustration.

3. Examine the leveling legs. Find the diamond marking.

4.

Screw the legs into the leg holes by hand. Use a wrench to
finish turning the legs until the diamond marking is no longer
visible.

5.

Place a carton corner post from dryer packaging under each

of the 2 dryer back corners. Stand the dryer up. Slide the
dryer on the corner posts until it is close to its final location.

Leave enough room to connect the exhaust vent.

1.

Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in

dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured

to exhaust hood with a 4" (10.2 cm) clamp.

2.

Move dryer into its final location. Do not crush or kink vent.

3.

(On gas models) Make sure that there are no kinks in the
flexible gas line.

4.

Once the exhaust vent connection is made, remove the
corner posts and cardboard.