Explosion hazard, Gas type, Natural gas – Kenmore HE2 110.9758 User Manual
Page 8: Gas supply connection requirements, Burner input requirements, Elevations above 10,000 ft (3,048 m), Gas supply pressure testing, Awarning, Gas supply reciyirerneris
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Gas Supply Reciyirerneris
AWARNING
U/
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (33 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result In death, explosion, or fire.
%" approved aluminum or copper tubing is acceptabie for
lengths under 20 ft (6.1 m) if local codes and gas supplier
permit.
If you are using Natural gas, do not use copper tubing.
%" flare X %" NPT adapter fitting between dryer pipe and %"
approved tubing.
Lengths over 20 ft (6.1 m) should use larger tubing and a
different size adapter fitting.
If your dryer has been converted to use LP gas, %" LP
compatible copper tubing can be used. If the total length of
the supply line is more than 20 ft (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of LP gas
must be used. Do not use TEFLON®* tape.
Must include a shutoff valve:
An individual manual shutoff valve must be installed in
accordance with the B149.1, Natural Gas and Propane
Installation Code. It is recommended that an individual
manual shutoff valve be installed within six (6) feet (1.8 m) of
the dryer and the location be easy to reach for opening and
closing.
A
C
E
Gas Type
Natural gas:
This dryer is equipped for use with Natural gas. It is design-
certified by CSA International for LP (propane or butane) gases
with appropriate conversion.
■ Your dryer must have the correct burner for the type of gas in
your home. Burner information is located on the rating plate
in the door well of your dryer. If this information does not
agree with the type of gas available, contact your local Sears
store or Sears Service Center.
LP gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting your gas company.
Gas supply line
Must include Vs" NPT minimum plugged tapping accessible
for test gauge connection, immediately upstream of the gas
connection to the dryer (see illustration).
*/
2
" IPS pipe is recommended.
B
D
A. W flexible gas connector
B. W pipe to flare adapter fitting
C. Va" NPT minimum plugged tapping
D. V
2" NPT gas supply line
E. Gas shutoff valve
Gas supply connection requirements
Use an elbow and a Ys" flare x %" NPT adapter fitting
between the flexible gas connector and the dryer gas pipe, as
needed to avoid kinking.
Use only pipe-joint compound. Do not use TEFLON®* tape.
This dryer must be connected to the gas supply line with a
listed flexible gas connector that complies with the standard
for connectors for gas appliances, CSA 6.10.
Burner input requirements
Elevations above 10,000 ft (3,048 m):
■ When installed above 10,000 ft (3,048 m) a 4% reduction of
the burner Btu rating shown on the model/serial number plate
is required for each 1,000 ft (305 m) increase in elevation.
Gas supply pressure testing
■ The dryer must be disconnected from the gas supply piping
system during pressure testing at pressures greater than
У
2
psi.
t©TEFLON is a registered trademark of E.i. Du Pont De Nemours and Company.