■ A level floor with a maximum slope of 1" (2.5 cm) under entire

dryer. (If slope is greater than 1" [2,5 cm], install Extended
Dryer Feet Kit, Part No. 279810.) Clothes may not tumble
properly and automatic sensor cycles may not operate
correctly if dryer is not level.

Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.

The dryer must not be installed or stored in an area where it will

be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.

NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.

Installation clearances

The location must be large enough to allow the dryer door to

open fully.

Dryer Dimensions

Custom undercounter installation - Dryer only

*Most installations require a minimum 5" (12.7 cm) clearance

behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this

dryer. This dryer has been tested for spacing of 0” (0 cm)
clearance on the sides and rear. Recommended spacing should
be considered for the following reasons:

■ Additional spacing should be considered for ease of

installation and servicing.

■ Additional clearances might be required for wall, door and

floor moldings.

■ Additional spacing should be considered on all sides of the

dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Fouvered doors with equivalent ventilation openings are
acceptable.

■ Companion appliance spacing should also be considered.

* Required spacing

Closet installation - Dryer only

(2.5 cm) (72.77 cm) (12.7 cm)

A

B

A. Side view - closet or confined area

B, Closet door with vents

‘Required spacing

"For side or bottom venting, 0" (0 cm) spacing is allowed.

Recessed or closet installation - Dryer on pedestal

A

B

A. Recessed area

B. Side view - closet or confined area

‘Required spacing

‘For side or bottom venting, 0" (0 cm) spacing is allowed.