Ifenting reqoirements, If using an existing vent system, If this is a new vent system – Kenmore ELITE OASIS Steam 110.6808 User Manual
Page 13: Vent material, Venting requirements, Warning
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
M
Ifenting Reqoirements
■ Remove excess flexible metal vent to avoid sagging and
kinking that may result in reduced airflow and poor
performanoe.
■ Do not install flexible metal vent in enclosed walls, ceilings or
floors.
Elbows
45° elbows provide better airflow than 90° elbows.
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
WARNING:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling or a concealed space of a building.
If using an existing vent system
■ Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.
■ Replace any plastic or metal foil vent with rigid or flexible
heavy metal vent.
■ Review Vent system chart. Modify existing vent system if
necessary to achieve the best drying performance.
If this is a new vent system
Vent material
■ Use a heavy metal vent. Do not use plastic or metal foil vent.
■ 4" (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFE™ venting products are recommended.
4" (10.2 cm) heavy metal exhaust vent
DURASAFE^“ vent products can be purchased from your
dealer. Eor further information, please call
1-800-4-MY-HOME® (1 -800-469-4663) or visit our website at
Rigid metai vent
■ For best drying performance, rigid metal vents are
recommended.
■ Rigid metal vent is recommended to avoid crushing and
kinking.
Flexible metal vent
■ Flexible metal vents are acceptable only if accessible for
cleaning.
■ Flexible metal vent must be fully extended and supported
when the dryer is in its final location.
u
Good
Better
Clamps
■ Use clamps to seal all joints.
■ Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into the interior of the
duct. Do not use duct tape.
Clamp
Exhaust
Recommended hood styles are shown here.
A Louvered hood style
B. Box hood style
The angled hood style (shown here) Is acceptable.
An exhaust hood should cap the vent to keep rodents and
insects from entering the home.
Exhaust hood must be at least 12" (30.5 cm) from the ground
or any object that may be in the path of the exhaust (such as
flowers, rocks or bushes, snow line, etc.).
Do not use an exhaust hood with a magnetic latch.
Improper venting can cause moisture and lint to
collect
indoors, which may result in;
■ Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
■ Housecleaning problems and health problems.
13