Kenmore 134966700 User Manual
Page 2
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
PRE-INSTALLATION REQUIREMENTS
Tools
Required for Installation:
1. Phillips screwdriver
2. 10 mm socket with ratchet.
3. Channel-lock adjustable pliers.
4. Carpenter's level.
absence of local codes, with the National Electrical
Codes, ANSi/NFPA 70 (latest edition). If in doubt,
call a licensed electrician.
DO NOT
cut off or alter
the grounding prong on the power supply cord. In
situations where a two-slot receptacle is present,
it is the owner's responsibility to have a licensed
electrician replace it with a properly
grounded
three prong grounding type receptacle.
ELECTRICAL REQUIREMENTS
CIRCUIT
-
Individ ual, properly polarized and grounded
15 amp. branch circuit fused with 15 amp. time delay
fuse or circuit breaker.
POWER
SUPPLY
- 2 wire, with ground, 120 volt, single
phase, 60 Hz, Alternating Current.
NOTE:
Because of
potential inconsistent voltage capabilities, the use of this
washer with power created by gas powered generators,
solar powered generators, wind powered generators or
any other generator other than the local utility company
is not recommended.
OUTLET RECEPTACLE
-
Properly grounded 3-prong
receptacle to be located so the power supply cord is
accessible when the washer is in an installed position.
NOTE:
GFI (Ground Fault Interrupter) receptacle is not
required.
GROUNDING REQUIREMENTS
A WARNING
Improper connection of the equipment
grounding conductor can result in a risk of electrical
shock. Check with a licensed electrician if you are in
doubt as to whether the appliance is properly grounded.
1. The washer
MUST
be grounded. In the event of
malfunction or breakdown, grounding will reduce
the risk of electrical shock by a path of least
resistance for electrical current.
2. Since your washer is equipped with a power supply
cord having an equipment-grounding conductor
and a grounding plug, the plug
MUST
b e
plugged
into an appropriate, copper wired receptacle that
is properly installed and grounded in accordance
with all local codes and ordinances or in the
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets
MUST
be installed within
42 inches (107 cm) of your washer's water inlet. The
faucets
MUST
be 3/4 inch (1.9 cm) garden hose type
so inlet hoses can be connected. Water pressure
MUST
be between 30 and 120 pounds per square inch (maximum
unbalance pressure, hot vs. cold, 10 psi.) Your water
department can advise you of your water pressure.
DRAIN REQUIREMENTS
1. Drain capable of eliminating 17 gals (64.3 L) per
minute.
2. A standpipe diameter of 1-1/4 in. (3.18 cm)
minimum.
3. The standpipe height above the floor should be:
Minimum height:
24 in. (61 cm)
Maximum height: 96 in. (244 cm)
NOTE:
Drain hose attached to the washer can reach a 79
in. (201 cm) high standpipe. For higher standpipe,
use hose P/N
134889610,
available from an
authorized parts distributor.