INSTALLATION INSTRUCTIONS

KEY DIMENSIONS AND SPECIFICATIONS

Description

Dryer (Gas and Electric)

Electrical Requirements

Please refer to the rating label.

Gas Requirements* NG:

6-8 in. WC

Gas Requirements* LP:

10-13 in. WC

Dimensions

27" (W) X 28 11/16" (D) X 38" (H), 52 1/4" (D With door open)

68.6cm (W) X 76.7cm (D) X 96.5cm (H), 132.7cm (D With door open)

Net Weight

Electric : 139 lb. (63.1kg) Gas : 142.4 lb. (64.6kg)

Drying Capacity

lEC 7.4 cu. ft.

m

Z

O

r

Z

*Gas Models only.

LOCATION REOUIREMENTS

IMPORTANT:
Read all installation instructions completely before
installing and operating your dryer!
It is important that you review this entire manual before
installing and using your dryer. It contains detailed
instructions concerning electrical connections, gas con­
nections and exhaust requirements.

CHOOSE THE PROPER LOCATION

• Store and install the dryer where it will not be exposed

to temperatures below freezing or exposed to outdoor
weather conditions.

• Choose a location with a solid, level floor.

• If the dryer is being installed in a garage, place the

dryer at least 18 in. (45.7cm) above the floor.

• Properly ground the dryer to conform with all governing

codes and ordinances.

• To reduce the risk of electric shock, do not install

the dryer in damp or wet locations.

IMPORTANT: If you are installing your dryer in a
manufactured or mobile home, please refer to the

section Special Electrical Requirements for Mobile or
Manufactured Homes on page 12.

CLEARANCES

20 3/20"

(56.2 cm)

52 1/4"

(132.7 cm)

3"

(7.6 cm)

1"

(2.5 cm)

O O

j

C

^ 1

-—^—-Ik-

1"

(2.5 cm)

Most installations require a minimum 5-1/2 in.
(14 cm) clearance behind the dryer for

the exhaust ducting.

Allow minimum clearances of at least 1 in.

(2.5 cm) on the sides and back to minimize

vibration and noise.

Allowing additional clearance for installation
and servicing is recommended.

Be sure to allow for wall, door, or floor moldings

that may increase the required clearances.

Allow at least 21 in. (53.3 cm) in front of the dryer
to open the door.

f

48 sq in.
(310 cm)

34 sq in.
(155 cm)'

O

f

3"

(7.6 cm)

(68.6 cm)

Additional Instructions for
closet installations:

• The closet door must allow

for sufficient airflow. Refer to
the diagram to the left for

minimum vent opening
requirements. A louvered

door is also acceptable.

Closet Door Vent

Requirements

8