CONNECTING ELECTRIC DRYERS (cont.)

CONNECTING ELECTRIC DRYERS

AWARNING:

• Connect the power cord to the terminal block.

Each colored wire should be connected to same

color screw. Wire color indicated on manual is con­

nected to the same color screw in block. Failure to

follow these instructions may result in a short or
overload.

Four-Wire Power Cord

<

A 4-wire connection is required for all mobile

and manufactured home installations, as
well as all new construction after January 1,

1996.

A UL-listed strain relief is required.

Use a 30-amp, 240-volt, 4-wire, UL-listed power

cord with #10 AWG-minimum copper conductor
and closed loop or forked terminals with upturned
ends.

O Remove the terminal block access cover on the upper

back of the dryer.

0 Install a UL-listed strain relief into the power cord

through-hole.

©Thread a 30-amp, 240-volt, 4-wire, UL-listed power

cord with #10 AWG-minimum copper conductor
through the strain relief.

■Neutral Grounding

Wire

Grounding through the neutral conductor is pro­
hibited for: (1) new branch-circuit installations, (2)

mobile homes, (3) recreational vehicles, and (4)
areas where local codes prohibit grounding

through the neutral conductor.

O Transfer the dryer’s ground wire from behind the

green ground screw to the center screw of the termi­
nal block.

0 Attach the two hot leads of the power cord to the outer

terminal block screws.

0

Attach the white neutral wire to the center screw of

the terminal block.

O Attach the power cord ground wire to the green

ground screw.

O TIGHTEN ALL SCREWS SECURELY.
0 Reinstall the terminal block access cover.

13

Three-Wire Power Cord

A 3-wire connection is NOT permitted on

new construction after January 1,1996.

■ A UL-listed strain relief is required.

■ Use a 30-amp, 240-volt, 3-wire, UL-listed power cord

with #10 AWG-minimum copper conductor and closed

loop or forked terminals with upturned ends.

(/}

O

z

UJ

o

Remove the terminal block access cover on the upper

back of the dryer.

@ Install a UL-listed strain relief into the power cord

through-hole.

©Thread a 30-amp, 240-volt, 3-wire, UL-listed power

cord with #10 AWG-minimum copper conductor
through the strain relief.

O Attach the two hot leads (black and red) of the power

cord to the outer terminal block screws.

0

Attach the neutral wire to the center terminal block

screw.

0

Connect the external ground (if required by local

codes) to the green ground screw.

© TIGHTEN ALL SCREWS SECURELY.
O Reinstall the terminal block access cover.