A warning, Fire hazard, Potential fire hazard – Whirlpool Thin Twin User Manual
Page 7: Warning
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
A
WARNING
Fire Hazard
Do Not use nonmetal, flexible duct. Do Not use metal duct smaller that four inches in diameter. Do
Not use exhaust hoods with magnetic latches. Improper air supply for exhausting may result in a
fire. Check that the exhaust system is not longer than specified. Exhaust systems longer than
specified will:
•
Accumulate lint
•
Shorten the life of the product
•
Reduce performance and result in longer drying times and increased energy usage.
Failure to follow these specifications may result in a fire.
Do Not exhaust dryer into a chimney, furnace cold air duct, attic or crawl space, or any other duct
used for venting. Clean the exhaust system every other year. Do Not install flexible duct under
wall, ceiling or floor materials. Accumulated lint could result in a fire or cause moisture damage.
A
WARNING
Fire Hazard
M
l
Connect dryer to a regulated gas supply. LR gas supply must not ex
ceed a pressure of 13" water column. This must be checked by a quali
fied person before installing the dryer. Use new, flexible tubing. Old
tubing may leak. All connections must be wrench-tightened. Do Not
check for gas leaks using an open flame. Failure to follow these instruc
tions could result in a fire or explosion.
A
WARNING
Potential Fire Hazard
The dryer must be exhausted outside. If dryer is installed in a closet, the
dryer MUST be exhausted outside. Failure to do so increases the risk of
fire.
VI