Appendix g: factory settings, Nt960/pci host adapter, Table 9: nt960/pci sw1 factory settings – Connect Tech NT960/PCI User Manual
Page 82: Appendix g: factory settings -30, Nt960/pci host adapter -30, Table 9: nt960/pci sw1 factory settings -30, Warning

4-30
Chapter 4: Appendix G - Factory Settings
Intellicon-NT960/PCI User's Manual, ver. 0.02
Appendix G: Factory Settings
This section summarizes the factory settings for the following
Intellicon-NT960/PCI hardware components:
Intellicon-NT960/PCI
Host
Adapter
Intellicon-NT960/PCI ACM/16, ACM/16RJ and
ACM/Flex16
ACM/Flex16 RS-485 SLIM
WARNING
Do not use a pencil to set the DIP switches as the lead graphite
may short-circuit the switch.
Your Intellicon-NT960/PCI adapter, ACM/Flex16 and Serial Line
Interface Module (SLIM) are very sensitive to static electricity.
Make sure that before you remove them from the anti-static
shipping bag, you wear an anti-static wristband. When you
remove them from the anti-static bag, handle them only by the
edges and place them on the anti-static bag or an anti-static mat.
NT960/PCI Host Adapter
The NT960/PCI Host Adapter ships with factory settings for the
following:
Table 9: NT960/PCI SW1 factory settings
Switch Position Configuration
ON
1 2 3 4 5 6
SW1
Switch 6 on DIP switch block SW1 set
on
.
One to 8 ACM modules stacked together,
with only one bus cable between the
NT960/PCI Host adapter and the first ACM
module.
Note:
Switches 1 through 5 are set off and must not be changed.