Table 8: rs-485/422 slim; line load options, Table 8: rs-485/422 slim; line load options -16 – Connect Tech NT960/PCI User Manual
Page 68

4-16
Chapter 4: Appendix D - RS-485/422 Option
Intellicon-NT960/PCI User's Manual, ver. 0.02
Table 7: RS-485/422 SLIM; port/switch block relation
Port
number
SLIM
socket
Switch
block
Port
number
SLIM
socket
Switch
block
1 SM1
S4
9 SM3
S4
2 SM1
S3
10 SM3
S3
3 SM1
S2
11 SM3
S2
4 SM1
S1
12 SM3
S1
5 SM2
S4
13 SM4
S4
6 SM2
S3
14 SM4
S3
7 SM2
S2
15 SM4
S2
8 SM2
S1
16 SM4
S1
Table 8: RS-485/422 SLIM; line load options
Switch
Position
Configuration
(when OFF)
Configuration
(when ON)
1
TxD load is removed
TxD load enabled (150 ohms)
2
RTS load is removed
RTS load enabled (150 ohms)
3 & 4
RxD disconnected from
bias and load circuits
Note: These two switches
MUST be used together
RxD connected to bias and
load circuits
5
RxD load is AC (150
ohms in series with 50 nF
and > 50 metres in length)
RxD load is DC (150 ohms
and < 50 metres in length)
6
CTS load is AC (150
ohms in series with 50 nF)
CTS load is DC (150 ohms)
Technical Tip: We recommend that you set the switches 3, 4 and
5 on the RS-485/422 SLIM to the
ON
(up) position for most RS-
485 configurations.