beautypg.com

Antari F-3 User Manual

Page 7

background image

7

parameters are automatically stored in non-volatile memory, allowing the machine to be

powered down without losing function settings.

The control buttons are: FUNCTIONUpDownTIMERVOLUME and MANUAL. You

can program the necessary menu settings with the control panel when the display indicates

»Ready To Fazer«.

1. Menu settings with the button FUNCTION

Setting time intervals for timer operation

Press the button FUNCTION until the display indicates »Interval Set«. Use the buttons

UP and DOWN to adjust the intervals between the individual fog outputs in timer mode

within the range of 5 and 200 seconds.

Setting the output duration for timer operation

Press the button FUNCTION until the display indicates »Duration Set«. Use the buttons

UP and DOWN to adjust the duration of the fog outputs in timer mode within the range of

5 and 200 seconds.

Setting the fog output volume for timer operation

Press the button FUNCTION until the display indicates »Timer Out«. Use the buttons UP

and DOWN to adjust the fog output volume in timer mode within the range of 2 % and

100 %.

Setting the fog output volume for continuous operation

Press the button FUNCTION until the display indicates »Volume Output«. Use the

buttons UP and DOWN to adjust the fog output volume in continuous mode within the

range of 2 % and 100 %.

Setting the fan speed