Sk-acp installation & operating manual, Specifications – American Access Systems ProAccess 200sa User Manual
Page 20

SK-ACP
Installation & Operating Manual
B-2
PHYSICAL
Depth
3.0”
(7.62 cm)
Width
10.0”
(25.40 cm)
Height
11.0”
(27.94 cm)
Weight
68.8 oz
(1.95 kg)
Housing Material is All Steel; Color is Beige
POWER REQUIREMENTS
16.5-24 VAC, 20 VA or 16-30 VDC, 100 mA plus reader current draw
Power Supply Sold Separately
*
A 12 VDC Power Supply may be used if connected to Battery Back-Up Leads.
BACK-UP BATTERY
12 V, 1.2 - 6 Ah (Optional, Sold Separately)
CARD READERS
Connect two card readers with two-line Wiegand output, up to 40 bits.
Provides 14 VDC, 150 mA max. power for each card reader.
SOFTWARE
SK-NET
TM
Software Version 2.0 or greater
OUTPUTS -
2 Per Door (Total of 4)
Latch & Alarm Shunt
DPDT contact, 2A, up to 220 VAC or 30 VDC
Auxiliary
DPDT contact, 2A, up to 220 VAC or 30 VDC
INPUTS -
2 Per Door (Total of 4)
Auxiliary 1
Requires SPST contact closure
Auxiliary 2
Requires SPST contact closure
COMMUNICATION
RS-232
5-Wire Shielded Cable, up to 38.4K baud, full duplex, (8N1)
RS-485
Single Twisted Pair, shielded cable with a signal ground
Wiegand Input (2)
Programmable up to 40 bits
14 VDC @ 150 mA supplied to each reader,
Modem
Requires Hayes compatible - 1.2 to 38.4k baud
Printer
Serial Printer (or Parallel printer with serial converter)
ENVIRONMENT
Ambient Temperature
-40° F to 158° F (-40° C to 70° C)
Humidity
0% to 95% relative humidity (non-condensing)
OPERATIONAL
Card Capacity
65,535/Door (Highest card number = 65,535)
Time Zones
15 for card access, one door unlock; full week plus
holiday in one-half hour segments; 32 programmable
holidays; selectable automatic daylight saving time.
Facility Code
Up to 16 different codes simultaneously (max. # of cards 65,535)
Latch/Alarm Shunt Timer
Programmable from 1/4 to 30 seconds
Antipassback
Real or Timed (1 to 30 minutes); hard or soft
Auxiliary Inputs (2)
Programmable for door monitor, tamper monitor, remote
open, remote inactive, bell, arming circuit or user defined
Auxiliary Output (1)
Output is programmable to activate under one of many
possible alarm conditions, time zone or card violations.
Limited Use Cards
4,000 (in a block within 65,535) programmable from
1-500 uses, days, weeks or number of days after first use.
Transaction Storage
4,864 events
Memory
Non-volatile
This product complies with UL 294 Standards, CE (European Standards), and with Part 15 of Class B FCC Rules.
Per Door
{
SPECIFICATIONS
SK-ACP-LE