Wiring and system configurations, Sk-acp installation & operating manual appendix a, Multi-panel system using sk-net – American Access Systems ProAccess 200sa User Manual
Page 17: Software- single location, Single panel system using sk-net, Software

SK-ACP
Installation & Operating Manual
APPENDIX A
WIRING AND SYSTEM CONFIGURATIONS
A-1
¿
Pentium 200 Mhz
NET-CONV-P
RS232-RS485
CONVERTER
NETWORK CABLE:
RS-485 - Two Twisted Pair, 18-24 AWG. Total
system cable length: 4,000 ft. Suggested Cable:
Belden 1585A.
1
SERIAL CABLE:
RS-232 - PC or printer to SK-ACP, 6-Conductor,
Shielded, 18-24 AWG. 300 ft. (9600 baud);
100 ft. (38.4 baud). Note: Cable used for RS232
Belden 6304FE maybe used to connect proximity
readers to the SK-ACP.
2
3
ALTERNATE PC LOCATION:
PC can be connected to network through any
SK-ACP’s serial port.
DAISY CHAIN / MULTIDROP
STAR / FANOUT
STUBBED
“T” CONFIG
SK-NET
TM
SK-ACP
SK-ACP
SK-ACP
SK-ACP
SK-ACP
SK-ACP
SK-ACP
SK-ACP
SK-ACP
SK-ACP
SK-ACP
¿
2
3
¿
2
¿
1
1
¿
SERIAL PRINTER
MONITORS ALL
SYSTEM ACTIVITY
NOTE: Each SK-ACP above can support 2 Wiegand
output card readers.
1
SK-NET
TM
SOFTWARE
MULTI-PANEL SYSTEM USING SK-NET
TM
SOFTWARE- SINGLE LOCATION
SK-NET
TM
SOFTWARE
SK-NET
TM
SOFTWARE
RS-485
OR
Pentium 200Mhz
RS-232
¿
¿
NET-CONV-P
¿
1
2
SK-ACP
CARD READER WITH ANY CARD
TECHNOLOGY, WIEGAND OUTPUT,
UP TO 40 BITS
SINGLE PANEL SYSTEM USING SK-NET
TM
SOFTWARE