beautypg.com

Installation – Vermont Casting DVR28IN User Manual

Page 9

background image

20012301

9

Vermont Castings DVR28 Direct Vent Gas Fireplace

Restrictor Plate Installation

The DVR28IN is shipped with a restrictor plate for ex-
tended pipe runs other than straight out installations. A
guide for usage is shown in Figure 10.
NOTE: Some installations may require some adjust-
ment by the installer for optimum flame appearance.
Optimum flame appearance would be a flame not
subject to tall dirty yellow flames or lifting of flames from
burner tube.

Installation

1. Remove front glass assembly. Refer to Window

Frame Removal section on Page 19.

2. Remove three (3) screws securing flue diverter to top

of combustion case. Remove flue diverter. (Fig. 9)

CAUTION: Use care not to damage rear refractory.
3. Remove two (2) screws on sides of flue opening.
4. Install restrictor plate with two (2) screws removed

from back of unit. (Fig. 9)

5. Re-install flue diverter with three (3) screws removed

earlier.

6. Reinstall glass assembly. (Refer to Page 19)

Figure 10

Examples for Extended Run/Restrictor Plate Settings
1. 90° Elbow, vertical 8’ (2.4 m), 90° elbow, out 20’ (6 m)
2. 90° Elbow, vertical 11’ (3.4 m), 90° elbow, out 13’ (4 m)
3. 90° Elbow, vertical 20’ (6 m), 90° elbow, out 7’ (2 m)
4. 90°, 40’ (12 m) vertical
Flue restricted to

:

1. 1¹⁄₈” (29 mm) opening in flue pipe outlet
2. 7/8” (22 mm) opening in flue pipe outlet
3. 3/4” (79 mm) opening in flue pipe outlet
4. 1³⁄₈” (35 mm) opening in flue pipe outlet

Fig. 9 Install restrictor plate for optimum flame appearance.

������
���������������
����

Flue Diverter

Remove

Three (3)

Screws

FP1789

������
�������������
����

Remove

Two (2)

Screws

Flue

Opening

FP1788

������
������������������
����

Restrictor

Plate

FP1790

Refer to Fig. 10

Pilot

Main

AF-4000

Solenoid

Red

Black

White or Green
Green or White

Orange or White

AF-4000B/P

Orange

Red

Brown

Black

HI/LO DC Battery Pack

Main
Module

Black

Gnd

Brown

Brown

Black

Red

Optional DC
Battery Back-up

FP1750
DVR28 wiring diagram
2/07

Red

Black

Optional IMTFK
Wall Thermostat
(for Bedroom Use
Canada ONLY)*

Learn Button

Remote/Off Switch

Continuous
Pilot ON/OFF
Switch

Fig. 8 DVR28 wiring diagram.

FP1750

FP1796
Wireless remote
3/07

ON

OFF

HI

LO

Wireless Remote

No wiring

required.

(Refer to

Pages

6,18, 21)

*NOTE: If optional IMTFK wall thermostat is installed,
switch on module for remote/off switch must be in the
“OFF” position. When the wall thermostat is used, wall
transmitter supplied with DVR28IN cannot be used at
this time.