10

The statistical functions are reached by pressing the “Information” key. Repetitive presses of the

“Information” key will cycle through the standard statistics mode until cycled back to time of day

display. Once either of the Information menus is entered the information shown for each display is

outlined below:

• Flow Rate - This display will only show if the flow meter is

attached to the control. The display shall show the current flow

rate of the water passing through the control. The display will

show the “Flow Rate” and “GPM” icons and the current flow

rate passing through the flow meter for as long as the “-” key or

“Information” key is not pressed.

• Capacity Remaining (%)(standard statistics) - This

display will only show if the flow meter is attached to the control.

The display shows the percent capacity remaining before

regeneration will be triggered. The display will show the “Water

Usage”, “Remaining” and “%” icons.

• Today’s Water Usage - This display will only show if the

flow meter is attached to the control. The display will show the

accumulated flow of water for the current day. The value is to

start totalizing at 12:00 AM and reset to 0 at 11:59:59 PM. The

display will show the “Today’s”, “Water Usage” and “Gallons”

icons and the total days flow.

• Average Daily Water Usage - This display will only show if

the flow meter is attached to the control. The display will show

a running 7-day average of daily water usage. The display will

show the “Avg Daily”, “Water Usage” and “Gallons” icons and

the averaged flow value.

Statistic