Culligan Iron-Cleer Plus User Manual
Page 13
9
• Filter Media Life (Change Media) - This setting is used
in Filter Mode ONLY with flow meter attached. It enables or
disables an alarm code (“CHANGE MEDIA”) that indicates the
end of life for the filter media. The display will show “LIFE” in
the left most characters and toggle between “Y” and “N” in
the right most character with the “+” and “-“ keys. If “NO” is
selected, the alarm is disabled and the ‘Total Capacity’ setting will be treated as it is in Flow
Meter Mode (softener). If “YES” is selected, the alarm is enabled and will sound when the
‘Total Flow/Life of Unit’ statistic = ‘Total Capacity’ setpoint, indicating that it is time to change
the filter media.
Pressing “Program” key will save and advance to the next step.
• Total Capacity Set Point (Max Capacity) - This setting
is used to program a value that corresponds to the maximum
capacity that can be expected from a unit before it is completely
exhausted (no reserve). This setting will only appear if a flow
meter is connected to the circuit board. The display will show
the “REGEN” icon and “MAXCAP” for two seconds and then
display the “REGEN” and “GALLONS” or “LITERS” icons
(depending on DIPswitch #7 setting) and the setting numbers to
adjust. Adjust the value with the “Up” or “Down” keys.
When the capacity used equals this total capacity setting with
the “Life” feature off, the control will regenerate either immediately or at the time of regen based
on the “hidden programming menu” setting.
With the “Life” feature on, the control will use this setting to trigger the “Change Media” alarm.
Pressing the “Program” key will save the setting and move to the next programming step.
• Batch Set Point - This setting is used to set the trip point for
regeneration when in flow meter operation. It will only appear
if a flow meter is connected. The programmed setting displays
the actual set point to trigger regeneration. The display will
show the “REGEN” icon and “bAtCH” for two seconds and
then display the “REGEN” and “GALLONS” or “LITERS” icons
(depending on dip#7 setting) and the setting numbers to adjust.
Adjust the value with the “Up” or “Down” keys.
Pressing the “Program” key will save the setting and move to the
next programming step.
Programming
(cont.)
9999 99
OOO8 7O