beautypg.com

Culligan Iron-Cleer Plus User Manual

Page 13

background image

9

• Filter Media Life (Change Media) - This setting is used

in Filter Mode ONLY with flow meter attached. It enables or

disables an alarm code (“CHANGE MEDIA”) that indicates the

end of life for the filter media. The display will show “LIFE” in

the left most characters and toggle between “Y” and “N” in

the right most character with the “+” and “-“ keys. If “NO” is

selected, the alarm is disabled and the ‘Total Capacity’ setting will be treated as it is in Flow

Meter Mode (softener). If “YES” is selected, the alarm is enabled and will sound when the

‘Total Flow/Life of Unit’ statistic = ‘Total Capacity’ setpoint, indicating that it is time to change

the filter media.

Pressing “Program” key will save and advance to the next step.

• Total Capacity Set Point (Max Capacity) - This setting

is used to program a value that corresponds to the maximum

capacity that can be expected from a unit before it is completely

exhausted (no reserve). This setting will only appear if a flow

meter is connected to the circuit board. The display will show

the “REGEN” icon and “MAXCAP” for two seconds and then

display the “REGEN” and “GALLONS” or “LITERS” icons

(depending on DIPswitch #7 setting) and the setting numbers to

adjust. Adjust the value with the “Up” or “Down” keys.

When the capacity used equals this total capacity setting with

the “Life” feature off, the control will regenerate either immediately or at the time of regen based

on the “hidden programming menu” setting.

With the “Life” feature on, the control will use this setting to trigger the “Change Media” alarm.

Pressing the “Program” key will save the setting and move to the next programming step.

• Batch Set Point - This setting is used to set the trip point for

regeneration when in flow meter operation. It will only appear

if a flow meter is connected. The programmed setting displays

the actual set point to trigger regeneration. The display will

show the “REGEN” icon and “bAtCH” for two seconds and

then display the “REGEN” and “GALLONS” or “LITERS” icons

(depending on dip#7 setting) and the setting numbers to adjust.

Adjust the value with the “Up” or “Down” keys.

Pressing the “Program” key will save the setting and move to the

next programming step.

Programming

(cont.)

9999 99

OOO8 7O