HI HLPT SERIES LOAD POINT ASSEMBLY
Page 12
Four Leg Systems
Total Capacity
Model #
Pounds
Kn
HI 4T900-43
900
4
HI 4T1.8K-43
1.8K
8
HI 4T4.5K-43
4.5K
20
HI 4T9K-43
9K
40
HI 4T18K-43
18K
80
HI 4T45K-45
45K
200
TABLE 3: FOUR LEG SYSTEMS
Specifications
Operating Specifications
Rated Output (F.S.) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2+-0.002mV
Non-Linearity- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - +-0.018% R.O.
Hysteresis - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <+-0.025% R.O.
Zero Balance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <+-1.0% R.O.
Creep @ 5 Min. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <+-0.01% R.O.
Temp Effect Output- - - - - - - - - - - - - - - - - - - - - - - - - - - - - <+-0.0014% R.O./C
Temp Effect Sensitivity - - - - - - - - - - - - - - - - - - - - - - - - - - <+-0.0007% R.O./C
Input Resistance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1050 to 1200 Ohms
Output Resistance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1000 +- 1 ohm
Insulation Resistance - - - - - - - - - - - - - - - - - - - - - - - - - - - - >5000 megohms
Excitation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-15VDC
Safe Load Limit - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 200% Emax
Ultimate Load - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 300% Emax
Safe Side Load - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 100% Emax