6 | maintenance – GEA Bock FK20 User Manual
Page 18

18
09740-09.2013-DGbFIT
r
D
GB
F
I
TR
6.1 Preparation
6.2 Work to be carried out
6| Maintenance
FK20 / ...
120 N
145 N
170 N
120 TK
145 TK
170 TK
120 K
145 K
170 K
Designation
Art. No.
Art. No.
Art. No.
Art. No.
Art. No.
Set of gaskets
80200
80515
Valve plate kit
80240
80242
80201
80202
80514
Set of shaft seals
08002
Oil SP 46, 1 litre
02279
Oil SE 55, 1 litre
02282
Oil change: In principle, an oil change is not mandatory if the system is correctly manufactured
and operated. However, based on decades of experience we recommend that the following oil
change/service work is carried out:
-
First oil change during the first maintenance of the vehicle.
-
Then after every 5,000 operating hours, though no more than 3 years.
Annual checks: Check the tightness of the compressor, running noise, pressures, temperatures,
function of auxiliary devices.
Only use genuine Bock spare parts!
6.3 Recommended spare parts
WARNING! Before starting any work on the compressor:
Switch off the compressor and secure it to prevent a restart.
Relieve compressor of system pressure.
Prevent air from infiltrating the system!
After maintenance has been performed:
Connect safety switch.
Evacuate compressor.
Release switch lock.