Maintenance

BURNER ADJUSTMENT

It may be necessary to adjust the burners periodically, to compensate

for variables in gas characteristics. If you notice the burner flame pat-

tern is irregular (Refer to Figures 9a, 9b & 9c), it may be necessary

to adjust the air shutter opening at the front of the venturi tubes.
• The shutters are accessible under the control panel at the front of

the Grill. (Fig. 20)

• Use a screwdriver to loosen the locking screws. Open the shut-

ter just enough to achieve the desired soft, blue flames. Make

adjustments in small increments and allow the burner to come up

to operating temperature (10 min.) before making further adjust-

ments.

Always allow sufficient time for the Grill to cool to a safe tempera-

ture before handling or cleaning any of its components.

If burners are removed for cleaning or adjustment, always
confirm that they have been reinstalled correctly over the valve
outlets. (Fig. 21) The valves should extend into the burner
venturis 1/4” minimum.

Similar adjustment can be made to Rotisserie and/or Side
Burners, if so equipped.

Page 21

Care & Maintenance

����
������������������
����

Loosen the
Locking Screw

Turn Shutter

Clockwise to Open

B139

Figure 20

����
�������������������
����

1/4” Minimum

B140

Figure 21

Venturi Tube

Valve Outlet