- 4 -
3.3 Switch On - Using buttons
1. Momentarily depress the [set] button.
2. The instrument switches on in the
mode that was active when it was last
switched off (e.g., measuring mode).
3.4 Switch On - Using OPT-RS
Activate the LED of the OPTO-RS connector or transmit any command from the
peripheral equipment to switch the instrument on. The instrument responds with
its identification (SY225.xx.x).
3.5 Switch
off
1. Press the [set] button until the display disappears.
2. Remove the OPTO-RS connector, or disable the
LED of the connector.
NOTE: It is not possible to switch the instrument
off in preset input mode, or when the LED of the
OPTO-RS connector is illuminated.
3.6 Changing the battery
1. Change the battery when the “B” indicator
appears.Remove battery housing and insert
new battery, ensuring correct polarity.
2. Clear the display by pressing the [mode]
and [set] buttons.
NOTE: after changing the battery, the instrument
displays « RESET », then reverts to measuring mode
and displays 0.000 mm (or 0.00 mm)
3.7 Changing the direction of measurement permanently
1. Remove the rear cover and reverse the direction of the
switch.
2. Reset the instrument (press [mode] and [set] to clear
the display) to validate the change of direction of
measurement
- 9 -
7.0 O
PERATION WITH
OPTO-RS
CONNECTOR
7.1 Operating
modes
The dial gauge works in simplex mode: the displayed value is sent from the
instrument or requested from the peripheral equipment (pedal or request from
peripheral equipment). It can also be used with a duplex OPTO-RS connector. It
recognizes any command (ASCII character sent by the computer) as a request to
transmit the displayed value.
7.2 Inserting the OPTO-RS connector
Check that the connector is the right way round by
means of the polarizing slot. Insert the OPTO-RS
cable with the components facing the operator.
Neither the instrument nor the connector can be
damaged if the latter is inserted the wrong way
round.
7.3 Transmission
parameters
4800 Bd, even parity, 7 data bits, 2 stop bits
7.4 Operation in simplex mode
• Transmission from the instrument: select reference mode, then momentarily
depress [set] to transmit the displayed value. The value is transmitted regardless
of the status of the LED of the OPTO-RS connector. If the LED is extinguished,
the display remains frozen until [set] is pressed again or a transmission request is
made by the peripheral equipment.
• Transmission request by the peripheral equipment: transmission of the
measured value can be requested from the peripheral equipment (printer,
computer) in measuring and reference modes, by sending any ASCII character or
by interrupting the LED for 140 msec.
See operating manual of optical connector for details.
7.5 Error
messages
In the event of an error, the instrument sends the following message:
Measuring system error. Acknowledge by a data request or by
means of the [set] button.