beautypg.com

Checkline QB-LED User Manual

Page 9

background image

– 8 –

No.

Position of the

Selector Switch

(E)

Adjustable

Parameters

Description

Display

(3)

MENU

PHASE deg:

0…359

Delay setting between the trigger signal

and flash (in degrees relative to the

frequency

Phase sift (PHASE in deg)
Phase shift setting (in degrees, relative to the frequency) between the trigger signal and flash. This value

allows a fixed angle to be set between the trigger signal and flash.
• Example without external connection: The viewing position can be extremely precisely adjusted without

changing the flash frequency. You can shift the viewing position within a movement cycle.

• Example with external connection: The external trigger signal is triggered before the desired observation

point (= flash position of the stroboscope). This would mean that the connected stroboscope would

regularly flash too early. The PHASE deg setting adjusts the delay, altering the flash position of the

stroboscope by a set angle. This setting is not affected by the current rotational speed, which means that

the stroboscope will flash at the desired position even during rotational speed fluctuations or during the

start-up period.

How to select in the MENU
1. Turn the selector switch (E) to the MENU position.
2. Select which parameter (e.g. PHASE deg) you want to change by

turning the rotary/push knob (D).

3.

Push the rotary/push knob (D) to confirm a parameter selection. The number shown in the display will

begin to flash.
4. Select the desired value

by turning the rotary/push knob (D.)

5. Confirm and exit selection by

pushing the rotary/push knob (D).

The setting is now active.

NOTE:

The display and adjustable value can be changed by

turning the rotary/push knob (D).