Checkline QB-LED User Manual
Page 13
–12–
No.
Position of the
Selector Switch
(E)
Adjustable
Parameters
Description
Display
(7)
MENU
DIV:
1…2550
Pulse divider, max value 255.
This function is only possible when the
external trigger is selected
Pulse divider (DIV)
The pulse divider can be used to set a value x, by which the external trigger signal is then divided.
Example: when scanning a cog wheel, an external trigger (e.g. rotational speed sensor) sends our a signal
for each cog scanned. With a DIV value of 10, it will only flash once every 10 signals.
(8)
MENU
SLOW:
0…600
The flash frequency exceeds the trigger
frequency by the value selected.
This function is only possible when the
external trigger is selected
SLOW (slow motion)
The SLOW function allows the viewer to view movement in slow motion. The speed of the slow motion
depends on the flash frequency and corresponds to the value selected.
(10)
MENU
TRIG:
0 / 1
Selection of trigger signal edge
(increasing 0, decreasing 1.
This function is only possible when the
external trigger is selected
(11)
MENU
MEM IN:
1 … 5
Selected settings can be backed up in
five separate storage locations.
(11)
MENU
MEM OUT:
1 … 5
It is possible to read backed-up
settings.