Cypress Quad HOTLink II CYV15G0404RB User Manual
Page 22
![background image](/manuals/65538/22/background.png)
CYV15G0404RB
Document #: 38-02102 Rev. *C
Page 22 of 27
CYV15G0404RB Device RESET Characteristics Over the Operating Range
t
RST
Device RESET Pulse Width
30
ns
CYV15G0404RB Reclocker Serial Output Characteristics Over the Operating Range
Parameter
Description
Condition
Min.
Max.
Unit
t
B
Bit Time
5128
660
ps
t
RISE
[14]
CML Output Rise Time 20
−80% (CML Test Load)
SPDSELx = HIGH
50
270
ps
SPDSELx = MID
100
500
ps
SPDSELx =LOW
180
1000
ps
t
FALL
[14]
CML Output Fall Time 80
−20% (CML Test Load)
SPDSELx = HIGH
50
270
ps
SPDSELx = MID
100
500
ps
SPDSELx =LOW
180
1000
ps
CYV15G0404RB AC Electrical Characteristics
(continued)
Parameter
Description
Min
Max
Unit
PLL Characteristics
Parameter
Description
Condition
Min
Typ
Max
Unit
CYV15G0404RB Reclocker Output PLL Characteristics
t
JRGENSD
[14, 22]
Reclocker Jitter Generation - SD Data Rate
TRGCLKx = 27 MHz
133
ps
t
JRGENHD
[14, 22]
Reclocker Jitter Generation - HD Data Rate
TRGCLKx = 148.5 MHz
107
ps
CYV15G0404RB Receive PLL Characteristics Over the Operating Range
t
RXLOCK
Receive PLL Lock to Input Data Stream (cold start)
376k
UI
Receive PLL Lock to Input Data Stream
376k
UI
t
RXUNLOCK
Receive PLL Unlock Rate
46
UI
Note
22. Receiver input stream is BIST data from the transmit channel. This data is reclocked and output to a wide bandwidth digital sampling oscilloscope. The
measurement was recorded after 10,000 histogram hits, time referenced to REFCLKx± of the transmit channel.
Capacitance
[14]
Parameter
Description
Test Conditions
Max
Unit
C
INTTL
TTL Input Capacitance
T
A
= 25°C, f
0
= 1 MHz, V
CC
= 3.3V
7
pF
C
INPECL
PECL input Capacitance
T
A
= 25°C, f
0
= 1 MHz, V
CC
= 3.3V
4
pF