beautypg.com

3 safety information, 4 specifications, 1 electrical specifications – Windy Nation Solar Panel Charge Controller User Manual

Page 4: 2 physical specifications, 2 installation, 1 electrostatic (esd) precautions, Safety information, Specifications, Electrical specifications, Physical specifications

background image

CHC-1224-xx User Manual

Revision 2.0

1.3 S

AFETY

I

NFORMATION

Please read the installation and operating instructions carefully prior to use. Pay special attention to the

IMPORTANT

and

WARNING

statements in the manual.

WARNING:

Never install during a lightning storm or where unsafe voltages are present.

Solar panels produce power when exposed to light. Use caution when handling copper wiring.

Do not use with equipment that exceeds the rated power for this device.

1.4 S

PECIFICATIONS

1.4.1

Electrical Specifications

Parameter

CHC-1224-10

CHC-1224-30

Rated Charge Current

10 Amps

30 Amps

Rated Load Current

10 Amps

30 Amps

PV Input Voltage

50VDC (Max)

Typical Idle Consumption

At idle < 5mA

Overvoltage Protection

15.6V 31.2V

Low Voltage Indication

12.0V 24.0V

Overload Protection (DC load)

1.25 x Inom>60s

1.5 x Inom >5s

Short Circuit Protection

3x Inom

Boost Charge

14.4V 28.8V

Float Charge Voltage

13.6V 27.2V

Equalization Charge

14.6V 29.2V

Load Disconnection

11.1V 22.2V

Load Reconnection

12.5V 25.0V

Temperature Compensation

-30mV/

o

C -60mV/

o

C

1.4.2

Physical Specifications

Parameter

CHC-1224-10

CHC-1224-30

Dimension (H x W x D)

5.50” x 3.53” x 1.08”

(140mm x 90mm x 27mm)

5.59” x 3.94” x 1.34”

(142mm x 100mm x 34mm)

Unit Weight

0.31 lb. (142g)

0.33 lb. (150g)

Enclosure

IP30

Operating Temperature

-31

o

F to 131

o

F (-35

o

C to 55

o

C)

Operating Humidity

10 to 90% relative humidity (non-condensing)

Wire Size

Up to 6mm

2

Battery Type

Lead Acid including AGM and Flooded

2 INSTALLATION

 Insure all terminating connections are clean and tight to prevent arcing and overheating.
 The controller must be installed in an area that satisfies all of the following conditions:

1. Dry: Avoid any location where water can contact the controller
2. Cool: Ambient air temperature between 30°F and 105°F (0°C and 40°C)
3. Ventilated: Allow at least 2 in (50 mm) of clearance above and below and at least 1 in (25 mm) on

each side for proper air flow.

2.1 E

LECTROSTATIC

(ESD)

P

RECAUTIONS

All electronic circuits may be damaged by static electricity. To minimize the likelihood of electrostatic damage,
discharge yourself by touching an electrical ground (e.g.: copper pipe) prior to handling the unit and avoid

Page 4 of 12

windy

nation

05/06/2014

This manual is related to the following products: