3 safety information, 4 specifications, 1 electrical specifications – Windy Nation Solar Panel Charge Controller User Manual
Page 4: 2 physical specifications, 2 installation, 1 electrostatic (esd) precautions, Safety information, Specifications, Electrical specifications, Physical specifications

CHC-1224-xx User Manual
Revision 2.0
1.3 S
AFETY
I
NFORMATION
Please read the installation and operating instructions carefully prior to use. Pay special attention to the
IMPORTANT
and
WARNING
statements in the manual.
WARNING:
Never install during a lightning storm or where unsafe voltages are present.
Solar panels produce power when exposed to light. Use caution when handling copper wiring.
Do not use with equipment that exceeds the rated power for this device.
1.4 S
PECIFICATIONS
1.4.1
Electrical Specifications
Parameter
CHC-1224-10
CHC-1224-30
Rated Charge Current
10 Amps
30 Amps
Rated Load Current
10 Amps
30 Amps
PV Input Voltage
50VDC (Max)
Typical Idle Consumption
At idle < 5mA
Overvoltage Protection
15.6V 31.2V
Low Voltage Indication
12.0V 24.0V
Overload Protection (DC load)
1.25 x Inom>60s
1.5 x Inom >5s
Short Circuit Protection
3x Inom
Boost Charge
14.4V 28.8V
Float Charge Voltage
13.6V 27.2V
Equalization Charge
14.6V 29.2V
Load Disconnection
11.1V 22.2V
Load Reconnection
12.5V 25.0V
Temperature Compensation
-30mV/
o
C -60mV/
o
C
1.4.2
Physical Specifications
Parameter
CHC-1224-10
CHC-1224-30
Dimension (H x W x D)
5.50” x 3.53” x 1.08”
(140mm x 90mm x 27mm)
5.59” x 3.94” x 1.34”
(142mm x 100mm x 34mm)
Unit Weight
0.31 lb. (142g)
0.33 lb. (150g)
Enclosure
IP30
Operating Temperature
-31
o
F to 131
o
F (-35
o
C to 55
o
C)
Operating Humidity
10 to 90% relative humidity (non-condensing)
Wire Size
Up to 6mm
2
Battery Type
Lead Acid including AGM and Flooded
2 INSTALLATION
Insure all terminating connections are clean and tight to prevent arcing and overheating.
The controller must be installed in an area that satisfies all of the following conditions:
1. Dry: Avoid any location where water can contact the controller
2. Cool: Ambient air temperature between 30°F and 105°F (0°C and 40°C)
3. Ventilated: Allow at least 2 in (50 mm) of clearance above and below and at least 1 in (25 mm) on
each side for proper air flow.
2.1 E
LECTROSTATIC
(ESD)
P
RECAUTIONS
All electronic circuits may be damaged by static electricity. To minimize the likelihood of electrostatic damage,
discharge yourself by touching an electrical ground (e.g.: copper pipe) prior to handling the unit and avoid