Steffes HPB22 Owners Manual User Manual
Page 7

- Page 4 -
C. HPB CONTROL DEVICES & SAFETY LIMIT DEVICES
(TABLE 2)
DEVICE
CONDITION
CATEGORY
NAME
LOCATION
MONITORED
ACTION
Control
Outdoor Air
Outside in a protected
Outdoor Air
Signals to the charge control
Devices:
Temperature
location providing
Temperature
system to set core charge
Sensor
representative outdoor
level in relation to outdoor
air temperatures. (See
temperatures (SeeTable1).
Outdoor Sensor Placement
in Installation Section)
Charge Control
HPB Electrical Section
Core Temperature
Maintains core tempera-
Thermostat
ture level in response to the
outdoor air temperature
sensor.
Low Temperature
Supply Duct (minimum
Supply Air
Modulates HPB mixing
Duct Sensor
of 3' downstream from
Temperature
damper to maintain
HPB supply discharge)
comfortable supply air
temperature (Stage 1
heat call).
Air Discharge
Air Discharge Outlet Port
HPB Discharge
Modulates HPB mixing
Controller
Air Temperature
damper to maintain
maximum HPB dis-
charge air temperature
(Stage 2 heat call).
130
o
Low Core
See Figure 10
Core Temperature
De-energizes HPB
Temperature
blower below preset
Switch
temperature
(See Table 3).
Safety
Core Charging High
HPB Limit Bar (See
Core Temperature
De-energizes HPB
Devices:
Limit Switches:
Figure 9)
resistance heating
(3) each HPB11B
elements.
(4) each HPB15B
(6) each HPB22B
Air Discharge
Air Discharge Outlet
HPB Air Discharge
De-energizes HPB
High Limit
Port
Temperature
blower when discharge
air exceeds 190
o
F.
Slam Gate
Air Discharge Outlet
HPB Air Discharge
At air discharge
Port
Temperature
temperature of 212
o
F,
fusible melt link re-
leases slam gate,
positively blocking
discharge air. All HPB
electrical functions de-
energized.